CGQLM - LATAPOXY 300 PART A
- MSDS: CGQLM
- Manufacturer: LATICRETE INTERNATIONAL INC
- Product Name: LATAPOXY 300 PART A
- National Stock Number: 8030-00N083491
Product Identification
Product ID:LATAPOXY 300 PART A
MSDS Date:04/27/1993
FSC:8030
NIIN:00N083491
Kit Part:Y
MSDS Number: CGQLM
Responsible Party
BETHANY, CT 06525
US
Emergency Phone: 203-393-0010
Info Phone: 203-393-0010
Preparer: S.B. FINE
Cage: 56877
Contractor
Telephone: 203-393-0010
Cage: 56877
Ingredients
SALICYLIC ACID; (2-HYDROXY BENZOIC ACID)
CAS: 69-72-7
RTECS: VO0525000
Fraction By Weight: <10%
OSHA PEL N/K
ACGIH TLV: N/K
1,2-ETHANEDIAMINE, N-(2-AMINOETHYL)-N'-(2-((2-
CAS: 112-57-2
RTECS: KH8585000
Fraction By Weight: <10%
OSHA PEL N/K
ACGIH TLV: N/K
PIPERAZINE, 1-(2-AMINOETHYL)-; (N-AMINOETHYLPIPERAZINE)
CAS: 140-31-8
RTECS: TK8050000
Fraction By Weight: <10%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: MAY CAUSE IRRIT OF RESPIRATORY
TRACT. COUGHING & CHEST PAIN MAY RESULT. EYES: CONTACT W/EYES
CAUSES SEVERE IRRIT & PAIN & MAY CAUSE BURNS, NECROSIS & PERMANENT
INJURY. BURNS OF EYE MAY CAUSE BL INDNESS. SKIN: CONTACT W/SKIN
QUICKLY CAUSES SEVERE IRRIT & PAIN & MAY CAUSE BURNS, NECROSIS &
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: PERMANENT INJURY. INGEST: MAY CAUSE
MALAISE, HEADACHE, NAUSEA, VOMITING &/OR DEATH UNLESS TREATED
PROMPTLY. CHRONIC: RPTD &/OR PRLNGD CONTACT W/SKIN MAY CAUSE
PRIMARY SKIN IRRIT & DERMATITIS . RPTD &/OR PRLNGD EXPOSURE TO LOW
CONCENTRATIONS OF VAPOR MAY CAUSE SORE THROAT, EYE IRRIT, NAUSEA,
HEADACHE.
Medical Cond Aggravated by Exposure:ASTHMA, CHRONIC RESPIRATORY DISEASE
(EG BRONCHITIS, EMPHYSEMA), KIDNEY DISORDERS, SKIN DISORDERS, LIVER
DISORDERS, ALLERGIES.
First Aid
First Aid:EYES: HOLD EYELIDS APART & IMMED FLUSH W/PLENTY OF WATER FOR
AT LEAST 15 MIN. CONTACT MD. SKIN: WASH AFFECTED AREA W/SOAP &
WATER. REMOVE CONTAMD CLTHG & SHOES. WASH BEFORE REUSE. VICTIMS OF
MAJOR SKI N AREA CONTACT SHOULD REMAIN UNDER MED OBSERVATION FOR AT
LEAST 24 HRS DUE TO POSSIBLE DELAYED EFFECTS. INHAL: MOVE PATIENT
AT ONCE TO FRESH AIR & CALL MD. KEEP ABSOLUTELY QUIET & START
OXYGEN(SUPDAT)
Fire Fighting
Flash Point Method:CC
Flash Point:220F,104C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . DO NOT BREATHE FUMES. USE WATER SPRAY TO REDUCE VAPORS.
Unusual Fire/Explosion Hazard:MAY GENERATE TOXIC, IRRITATING OR
FLAMMABLE COMBUSTION PRODUCTS. MAY SPREAD ON THE SURFACE OF WATER.
Accidental Release
Spill Release Procedures:ADMIX WITH NON-REACTIVE ABSORBENT AND PLACE IN
A CONTAINER FOR DISPOSAL. WEAR NIOSH APPROVED DUST MASK,
IMPERMEABLE GLOVES AND ANSI APPROVED SAFETY GLASSES. USE METAL
CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM OXIDIZERS, HEAT OR
FLAMES.
Other Precautions:DURING MAINTENANCE OF CONTAMINATED EQUIPMENT WEAR
NIOSH APPROVED DUST MASK, IMPERMEABLE GLOVES AND ANSI APPROVED
SAFETY GLASSES.
Exposure Controls
Respiratory Protection:A NIOSH APPROVED DUST MASK.
Ventilation:NORMAL VENTILATION.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
LONG SLEEVED CLOTHING.
Work Hygienic Practices:NORMAL GOOD HOUSEKEEPING METHODS.
Supplemental Safety and Health
FIRST AID PROC: INHALATION THRU SUITABLE EQUIP. ASSURE MUCOUS DOES NOT
OBSTRUCT AIRWAY. INGEST: CALL MD IMMED. INDUCE VOMITING OR REMOVE
STOMACH CONTENTS BY GASTRIC SUCTION ONLY AS DIRECTED BY MED PER S.
NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
Chemical Properties
Spec Gravity:0.95
Appearance and Odor:AMBER LIQUID WITH AN AMMONIA LIKE ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NOT APPLICABLE.
Hazardous Decomposition Products:NOT APPLICABLE.
Disposal
Waste Disposal Methods:DISPOSE OF ALL WASTES IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.